[Download] INVT GD100 User Manual PDF INVT Drive Manual PDF Programming, Installing & Troubleshooting Free Real

Hi Guys,

INVT Provides Low Voltage, Medium Voltage, General, and Dedicated Dives. INVT VFD is Mostly Used in Various types of Industrial Sectors and Others Sectors. INVT GD100 Drives is a Dedicated Drives. Before Installing, Programming, Maintenance the INVT GD100 Drives must be Read the Manuals. Today plchmiservo.com would like to share INVT GD100 Drives user manual and How to Program and Install the VFD. So please read the Manual Properly Otherwise you can face the Died or May Risk your Life, or May Damaged your Product.

Connection Diagram of INVT GD100 VFD

Parameter of INVT GD100 Series VFD

P00.00– Speed Control Mode- set 1 Senseless vector control Mode.

P00.01– Run Command Channel- Keypad Running or Terminal Running or Communication (0, 1, 2)

P00.02– Running Command Channel Selection- 0 MODBUS, PROFIBUS, Ethernet Communication, CANBUS

P00.03: Maximum Output Frequency (P00.04-400HZ)-50.00 HZ

P00.04– Upper Limit of Running Frequency -50.00 HZ

P00.05– Lower Limit of Running Frequency -0.00 HZ

P00.06– A Frequency Commend Selection- 0-Keypad Data Setting

P00.07-Keypad SetFrequency-50.00 HZ

P00.11-ACC Time 1-(0.0 Sec-3600 Sec) Depend on the Motor Type

P00.12-DEC Time 1-(0.0 Sec-3600 Sec) Depend on the Motor Type

P00.13- Run Direction Selection- If you set 0-Runs of the default Direction (Forward), If you set 1-Runs of the Opposite Direction (Reverse)

P00.15-Motor Parameter Auto Tuning

P03.24-Maximum Voltage Limit-0.0%-120.0%

Motor Parameter of INVT GD100 Series Inverter

P07.18-The Rated Power of the Inverter (KW) (0.4KW-3000KW)-Depend On the motor

P07.19-The Rated Voltage of the Inverter (V) (50V-12000V) – Depend On the motor

P07.20- The Rated Current of the Inverter (A) – (0.1A-6000A), Depend On the motor

P17.05-The Rotation of the Motor (0-65535 RPM)-

For JOG Speed Operation

P07.02-Quick/ Jog Function Selection- 1-Jogging Running

P08.06-Jogging Running Frequency-5HZ, 10 HZ, etc

P07.03-Jog Running Command- 0-Keypad Running

Multi-Function of INVT GD100 Series Inverter

Input Terminal Selection Function

P05.01-S1 terminal Function Selection-FWD Rotation Operation

P05.02-S2terminal Function Selection -REV Rotation Operation

P05.03-S3 terminal Function Selection -16: Multi-Stage Speed Control 1

P05.04-S4 terminal Function Selection -17: Multi-Stage Speed Control 1

P05.05-S5 terminal Function Selection -18: Multi-Stage Speed Control 1

P05.06-S6 terminal Function Selection -19: Multi-Stage Speed Control 1

P05.07-S7 terminal Function Selection –

P05.08-S8 terminal Function Selection –

Multi-Stage Speed Setting

P10.02 – Multi-Stage Speed 0 –
P10.03 – The “Running” Time off “Stage 0” –
P10.04 – Multi-Stage Speed 1 –
P10.05 –Running Time of Stage 1 –
P10.06 – Multi-Stage Speed 2–
P10.07 –”Running” Time of Stage 2 –

…………………………………………..

P10.32 – Multi-Stage Speed 15 –
P10.33 – Running Time of Stage 15 –

+INVT GD100 VFD User Manual PDF

Link: https://drive.google.com/file/d/14tRuuEo9xi4gXwjLhuXyD7UbQmCjiEzE/view?usp=sharing

If any problem with INVT VFD GD100 Series VFD Installing/Programming/Troubleshooting, Then please contact plchmiservo.com via mail/WhatsApp, Admin  will feedback to you as soon as possible via mail  or WhatsApp.

Thanks & Best Regards!!!