[Download] Panasonic VFD VF 200 Manual PDF Programming & Installing Free 100% Real
Hi Everyone,
Panasonic Provides Various Types of Industrial Products Programmable Logic Controller (PLC), Human Machine Interface (HMI), Servo Drive, Variable Frequency Drive (VFD), Sensors, etc Panasonic servo drive is very popular in the World. Panasonic Produce Various types of VFD Such as MK100, MK300 Series, MK500 Series, VF0 Series, VF100 & VF200, Today plchmiservo.com would like to share the Panasonic VFD VF 200 Manual and How to Program of VFD,
Before Installation of the Panasonic VFD VF200 Please read the Manual Properly of VFD otherwise you can face many problems, such as May Damage to your VFD or even you can die.
Model Description of VF200 VFD
Features of Panasonic VF200 Series VFD
+ Panasonic VF200 Series VFD Accepted the Company’s Original Vector Control Technology, and Low Speed but produce high Torque (1HZ to 150%)
+Panasonic VF200 VFD Used to Large Operation Panel.
+Easy to Operate and Easy to use
+Have High-Speed Current Limiting Protection System.
+Panasonic VF200 Series VFD has Output Short Circuit Protection.
+We can be Easily Copy parameters and Used to Another VFD
Connection Diagram
Single Phase Connection Diagram of Panasonic VF200 Series VFD
Three Phase Connection Diagram
For Single Phase: L & N-Power Supply, For Three Phases: R/L1, S/L2, and T/L3-Power Supply
Motor Connection Single and Three Phase are same: U, V, and W
Basic All Parameter of Panasonic VF200 Series VFD
P150- Password Set, If you Need (1-9999)
P151-Setting Data Clear/Factory Reset
P001-The 1st Acceleration Time (0.1 to 3600 sec)
P002-The 1st Deceleration Time (0.1 to 3600 sec)
P003-Run Commend Select- Panel/ External Control or Communication
P004-Frequency Setting Signal- Panel (Potentiometer or Digital Setting), External Control (Potentiometer, 0-5V, 0-10V) or Communication, Panel Potentiometer
P008– “Maximum” Output Frequency
P009– Base Frequency – (45 to 400 HZ)
P014: Max. Output Voltage (1 to 500V)
P029: Start Frequency (0.5to 60HZ)
P029: Stop Frequency (0.5to 60HZ)
P099– Lower Frequency Limit- range 0.5 to 400
P100– Upper Frequency Limit- range 0.5 to 400HZ
For JOG Speed Operation
P042– JOG Frequency (0.5 to 400HZ)
P043-JOG Acceleration time -0.1 to 3600s
P044– JOG Deceleration time-0.1 to 3600s
Multi-Function of Panasonic VF200 Series Inverter
P045- Multi-Speed Function Select
Multi-Speed Switch Function
P036- SW1 Function Select, Terminal 4
P037- SW2 Function Select, Terminal 5
P038- SW3 Function Select, Terminal 6
P039- SW4 Function Select, Terminal 7
P040- SW5 Function Select, Terminal 8
Multi-Step Speed Setting
P046-The 2nd Speed Frequency
P047-The 3rd Speed Frequency
P048-The 4th Speed Frequency
P049-The 5th Speed Frequency
P050-The 6th Speed Frequency
P051-The 7th Speed Frequency
P052-The 8th Speed Frequency
………………………………………………
P060-The 16th Speed Frequency
Range 0.5 to 400 HZ
P129-Vector Control Select
P130-Motor Capacity
P131- Motor Pole Number
>>> Download Google Drive Link Panasonic VF200 Series VFD>>>
+Panasonic VF200 Series VFD User Manual PDF
Link: https://drive.google.com/file/d/1T6z1g6Q2rXpbcJEE-MlV0m8eg0clL8IN/view?usp=sharing
If you face any Problem with Panasonic VF200 Series VFD Installing/Programming/Troubleshooting, Then please contact plchmiservo.com via mail, or you Comment below the Content. I will feedback to you as soon as possible via mail