Hi Friends,
Shenzhen MICNO Electric Co., Ltd (China) is a Manufacturer company of Synchronous Drive, Open Loop vector control Drives, Solar pump Inverters, Engineering Inverters also PLC, HMI, Servo, etc. MICNO Products are widely used in 80 overseas countries in the World especially Middle East Countries such as Africa, South America, South Asia, Southeast Asia, etc.
So Today plchmiservo.com would like to share the MICNO KE300A Series, KE300B Series, KE600, AE300 VFD User manual, and How to Programming MICNO KE300A Series inverter by Keypad.
For 1 Phase 220 V Wiring Connection Diagram
For 3 Phase Wiring Connection Diagram
Programming Parameter of MICNO KE300A Series VFD
At first set the parameter
P0-00-Set the Inverter Model (G or P Model Depend on VFD)
P0-02– Running Command Source- Where From we will RUN the VFD.
0: keypad
1: Terminal
2: Communication
Depending on the power/Voltage, MICNO Produce 200 V to 690V Inverter (1 and 3 Phase) sees the figure
P0-03– Main Frequency Source A Selection- 1 or See the Manual Where From we will Frequency control the VFD.
P0-07-Frequency Source Selection-0- Main Frequency Source Selection A-00
P0-08-Keypad ReferenceFrequency-50HZ
P0-09- Running Direction Selection-
0: Forward
1: Reverse
See the Keypad
P0-10: Maximum Frequency (50-300HZ)-50HZ
P0-12– Frequency Upper Limit-50HZ
P0-14– Frequency Lower Limit-0HZ
P0-17-Acceleration Time 1-(0.01 Sec-36000 Sec) Depend on Model
P0-18-Deceleration Time 1-(0.01 Sec-36000 Sec) Depend on Model
Motor Parameter of MICNO KE300A Series Inverter
P1-00-Set the Motor Type-0/1 Depend on motor
P1-01-Rated Power (KW) (0.1KW-1000KW)-Depend On the motor
P1-02-Rated Voltage (V) (1V-2000V) – Depend On the motor
P1-03-Rated Current (A) – (0.01A-6553.1A) Model Depend
P1-04-Rated Frequency (Hz) – (50HZ/60HZ etc) Model Depend
P1-05-Rated Speed (RPM) – (1RPM-36000 RPM)-Depend on Model for example 2800 RPM
For JOG Speed Operation
P8-00– Jog Running Frequency-
P8-00– Jog Acceleration Time (0.01 s to 3600s)
P8-00– Jog Deceleration Time (0.01 s to 3600s)-
Terminal Diagram see the Figure
Multi-Function of MICNO KE300A Series Inverter
P4 input Terminal Selection Function
P4-00-D1 terminal Function-FWD
P4-01-D2 terminal Function-REV
P4-02-D3 terminal Function-12: Multi-Step Speed Terminal 1
P4-03-D4 terminal Function-13: Multi-Step Speed Terminal 2
P4-04-D5 terminal Function-14: Multi-Step Speed Terminal 3
P4-05-D6 terminal Function-15: Multi-Step Speed Terminal 4
PC Group Multi-Step Command and Simple PLC and
PC-00 – Multi-Step Command 0 –
PC-01 – Multi-Step Command 1 –
PC-02 – Multi-Step Command 2 –
…………………………………………..
PC-15 – Multi-Step Command 15 –
>>> Download Google Drive Link MICNO KE300A VFD>>>
Link: https://drive.google.com/file/d/1nhKH44vlNHO0MBdPh3XtVN6MOssXqjFJ/view?usp=sharing
>>> Download Google Drive Link MICNO KE300B VFD>>>
Link: https://drive.google.com/file/d/1mba0WFV_DyGC_oxh0Zr0lN49lXVmQ6SR/view?usp=sharing
>>> Download Google Drive Link MICNO AE300 VFD>>>
Link: https://drive.google.com/file/d/1AfnwB7PNplgr-XpzUi9Rp1oh7-HXsSUj/view?usp=sharing
>>> Download Google Drive Link MICNO KE600 VFD>>>
Link: https://drive.google.com/file/d/12OvuZkJDmxCXUJwPHM-3B0rWhIlBf0ey/view?usp=sharing
>>> Download Google Drive Link MICNO VFD Software>>>
Link: https://drive.google.com/file/d/1QttAz3R2GVw5gKik-6fAxo-ViPXYBHNV/view?usp=sharing
If any problem with MICNO VFD KE300A Series VFD Programming, Troubleshooting, or Installing, contact plchmiservo.com via mail, I will feedback to you as soon as possible.