Hi Friends, Nietz Electric Co., Ltd is the Manufacturer and Supplier Company of Industrial Automation Sectors Products This Company was established in 2005. Nietz produces such as AC Servo Drives, Variable Frequency Drive (VFD), Motion Controller, etc. Nietz VFD is widely used in various industries, such as Textile, Compressor, packaging Machines, Printing Machines, Electronics, and Others Sectors. However, Today I would like to share the [Download] Nietz Inverter Manual NZ 2000 VFD Programming Manual Also How to Install and Program Nietz NZ2000, NL1000 & NL8000 VFD also share the User manual, How to download and set up the NZ2000 Series inverter, and How to Program by using it manually

Description of Programming Parameter of NIETZ NZ 2000 Series VFD:

How to set the Nietz  NZ 2000 VFD Parameter

At first set the parameter

P0.01-Control Mode Selection-0: Voltage/Frequency,

P0.02-Commend Channel Selection-0: Operation Panel Control (Panel Mode), If set Terminal Mode (External Mode)-1

P0.03– Frequency Source- 0: Main Frequency Source x

P0.04-Main Frequency Source X Selection-0: Digital Setting (P0.10 Preset Frequency…), 2: FIV (External Mode

Motor Parameter of Nietz NZ 2000 Inverter

P2.01-Rated Motor Power (KW)-2.2KW

P2.02-Rated Motor Voltage (V) – 220V/ 380V

P2.03-Rated Motor Current (A) – 2.2A

P2.04-Rated Motor Frequency (HZ)-(50HZ/60HZ

P2.05-Rated Motor Speed (RPM) – 2800 RPM

P0.08-Acceleration Time (10Sec, 15, 20, the 30S)

P0.09-Deceleration Time (10S, 20, the 30S)

P0.10-Frequency preset-50HZ Max

P0.11-Rotation Direction 0:  Same Direction (FWD), 1: Reverse Direction (REV)

P0.12-Maximum Frequency-50HZ (50HZ-320HZ)

P0.14-Upper Limit Frequency-50HZ

If Need P0.15-Upper Limit Frequency Offset-For Example 40HZ etc

P0.16-Lower Limit Frequency-(0.00HZ-Upper Limit Frequency P0.14), Set: 00HZ

For JOG Operation

P8.00– Jog Running- Max Frequency-10HZ, 15HZ, 20HZ, 30HZ, etc

P8.01– Jog Acceleration-10S, 15S, etc

P8.02– Jog Deceleration-5Sec, 10 Sec, etc

P5.02– S1 Function Selection- Setting Range-4: FWD Jog

P5.03– S2 Function Selection- Setting Range-5: REV Jog

For Multi-Function

P0.04-Multistage Instruction-6

P5.02-Multi Reference terminal-1, S1-12

P5.03-Multi Reference terminal-2, S2-13

P5.04-Multi Reference terminal-3, S3-14

P5.02-Multi Reference terminal-4 S1-15

Then set the Multi-Function Frequency Setting

 PC: 00 -Reference 0- Example-0Hz

PC: 01- Reference 1- Example-10Hz

PC: 02- Reference 2-Example-20Hz

PC: 03 -Reference 3-Example-30Hz

…………………………………………..

PC: 16-Reference 16- Example-100Hz

>>> Google Drive Link Nietz All Series Inverter>>>

We have given the [Download] Nietz Inverter Manual NZ 2000 VFD Programming Manual Google drive link, so click on the link to download the Nietz VFD User Manual.

Nietz NZ2000 Series VFD Manual PDF

+ [Download] Nietz Inverter Manual NZ 2000 VFD Manual PDF

Link: https://drive.google.com/file/d/1FoGb69ZQQLKcQ8GDJnTGzno5C0JTOYrd/view?usp=sharing

Nietz NL1000 Series VFD Manual PDF

+ [Download] Nietz Inverter Manual NL 1000 VFD Manual PDF

Link: https://drive.google.com/file/d/1jVLu_zfbMhwGUqJGwAuUhx3G8RnWL7dd/view?usp=sharing

Nietz NL8000 Series VFD Manual PDF

+ [Download] Nietz Inverter Manual NL 8000 VFD Manual PDF

Link: https://drive.google.com/file/d/16Ys7GllxF4r5QEr-6anS0gsFV7t7E3BB/view?usp=sharing

If Any problem with Nietz NZ 2000 Series VFD Parameter Setup or Installation or Manual Link is not Found Please contact plchmiservo.com via mail Also If you think Nietz VFD Content is very helpful for you then please like our content and share the content with your friends.

Thanks!!!

##Other Need Software

+LS VFD Software Free Download Link

+Shihlin VFD Software Download